EXTERNAL FIRE FIGHTING SYSTEMS (Fi-Fi I,II,III)


Aksis supplies external fire fighting systems from the world’s leading supplier Fire Fighting Systems AS (FFS)
NON – CLASSED FIFI VESSELS (Fi-Fi O)
Any type of vessel with an external FiFi system but without any formal classification will be covered under this heading. Normally capacities between 37 m3 / h and u p to FiFi I ( 2400 m3 / h) are used. Fire water for the monitors may be supplied by one ore more fire pumps, driven by dedicated diesel engines, PTO gearboxes or electrically driven pumps, The monitors can be either remote controlled (recommended) or manual.
Fi-Fi l
The class notation FiFi I means that the vessel is to be equipped with minimum 2 fire monitors, able to throw water to a minimum distance of 120 meters from the vessel and to a height of minimum 45 meters. The monitors are to be remote controlled from the wheelhouse. Since the fire pumps and related equipment are located in the engine room these are also normally remote controlled, FiFi I Systems are normally installed on Escort tugs, Fire fighting vessels etc.
Fi-Fi ll
The class notation FiFi II means that the vessel is to be equipped with minimum 2 fire monitors, (DNV rules) able to throw water to a minimum distance of 180 meters from the vessel and to a height of minimum 110 meters, or if other classification for the vessel (i.e. LRS, ABS, R.I.N.A, BV, GL etc), the vessel is to be equipped with 3 or 4 fire monitors, able to throw water to a minimum distance of 150 meters from the vessel and to a height of minimum 7Ometers, Whatever configuration is chosen for the FIFI II vessel the total water capacity shall be not less than 7200 m3/h, The monitors are to be remote controlled from the wheelhouse, Since the fire pumps and related equipment are located in the engine room these are also normally remote controlled. FiFi II Systems are normally installed on offshore vessels like Anchor-handling tug / supply vessels, or other specialised vessels.
Fi-Fi III
The class notation FiFi III means that the vessel is to be equipped with minimum 3 fire monitors, (DNV rules) able to throw water to a minimum distance of 180 meters from the vessel and to a height of minimum 110 meters, or if other classification for the vessel (i.e. LRS, ABS, R.I.N.A, BV, GL etc), the vessel is to be equipped with 4 fire monitors, able to throw water to a minimum distance of 150 meters from the vessel and to a height of minimum 7Ometers, Whatever configuration is chosen for the FIFI II vessel the total water capacity shall be not less than 9600 m3/h, The monitors are to be remote controlled from the wheelhouse, Since the fire pumps and related equipment are located in the engine room these are also normalIV remote controlled. FiFi III Systems are not so common, but are normally installed on larger offshore vessels, or other specialised vessels.